Notifications
You must be signed in to change notification settings - Fork 0
/
ceph_ec_calc.py
122 lines (105 loc) · 4.64 KB
/
ceph_ec_calc.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
#!/usr/bin/env python3
import argparse
import sys
parser = argparse.ArgumentParser(description="Ceph EC calculator - calculate EC using servers,drives,capacity OR osds,capacity",
formatter_class=argparse.ArgumentDefaultsHelpFormatter)
parser.add_argument("-s", "--servers", type=int, default=6, help="number of servers")
parser.add_argument("-d", "--drives", type=int, default=12, help="drives per server, where each is an OSD")
parser.add_argument("-o", "--osds", type=int, default=0, help="total number of OSDs, this supersedes usage of servers*drives, capacity should still be used")
parser.add_argument("-c", "--capacity", type=int, default=12, help="drive capacity (TB) - AKA OSD size")
parser.add_argument("-k", "--chunks", type=int, default=4, help="EC chunks")
parser.add_argument("-m", "--parity", type=int, default=2, help="EC parity chunks")
parser.add_argument("-t", "--table", action='store_true', help="Print in tabulate form")
args = vars(parser.parse_args())
# *** VARS *********************
#SERVERS/OSDs
SERVER_COUNT=args["servers"]
OSD_COUNT=args["osds"]
#EC
EC_K=args["chunks"] #number of chunks to divide object into
EC_M=args["parity"] #additional parity chunks
EC_TOTAL=EC_K+EC_M #total chunks, added for check only
#DRIVES
DRIVE_SIZE=args["capacity"] #TB
DRIVE_PER_SERVER=args["drives"]
#*** CHECKS *********************
if OSD_COUNT < 0:
print("ERROR - CANT HAVE NEGATIVE OSD COUNT")
sys.exit(1)
if OSD_COUNT == 1:
print("ERROR - CANT HAVE OSD COUNT OF 1")
sys.exit(1)
if SERVER_COUNT < 1:
print("ERROR - SERVER_COUNT SHOULD BE > 1")
sys.exit(1)
if EC_K < 2:
print("ERROR - K CHUNKS SHOULD BE > 2")
sys.exit(1)
if EC_M < 1:
print("ERROR - M PARTITY SHOULD BE > 1")
sys.exit(1)
if DRIVE_SIZE < 1:
print("ERROR - DRIVE_SIZE SHOULD BE > 1")
sys.exit(1)
if DRIVE_PER_SERVER < 1:
print("ERROR - DRIVE_PER_SERVER SHOULD BE > 1")
sys.exit(1)
if EC_M >= EC_K:
print("ERROR - M PARITY MUST BE LESS THAN K CHUNKS")
sys.exit(1)
if (EC_TOTAL > SERVER_COUNT and OSD_COUNT <= 0) or (EC_TOTAL > OSD_COUNT and OSD_COUNT > 1):
print("ERROR - SERVER_COUNT OR OSD_COUNT SHOULD BE >= EC CHUNK TOTAL (K+M)")
print("K WAS "+str(EC_K))
print("M WAS "+str(EC_M))
print("EC CHUNK TOTAL WAS "+str(EC_TOTAL))
sys.exit(1)
# ***CALCULATIONS **
EFFICIENCY=float(EC_K/(float(EC_K+EC_M)))
# ***CALCULATIONS CONT. (IN TB)***
#use OSD count if specified
if OSD_COUNT > 1:
RAW=(OSD_COUNT*DRIVE_SIZE)
else:
#if OSD_COUNT NOT USED, USE SERVER+DRIVES COUNTS
SERVER_SIZE=(DRIVE_SIZE*DRIVE_PER_SERVER)
RAW=(SERVER_COUNT*SERVER_SIZE)
FULL_USAGE=float(EFFICIENCY*RAW)
EIGHTY_FULL_USAGE=float(0.80*FULL_USAGE)
if args["table"] != True:
# ***OUTPUT ***
if OSD_COUNT == 0:
print("----")
print("**** Using --servers NOT --osds ****")
print("----")
print("-c "+str(DRIVE_SIZE)+" | Using DRIVE|OSD_SIZE (TB) "+str(DRIVE_SIZE))
print("-d "+str(DRIVE_PER_SERVER)+" | Using DRIVE|OSD_PER_SERVER "+str(DRIVE_PER_SERVER))
print("-s "+str(SERVER_COUNT)+" | Using SERVER_COUNT "+str(SERVER_COUNT))
print("Results in SERVER_SIZE (TB) "+str(SERVER_SIZE))
if OSD_COUNT > 1:
print("----")
print("**** Using --osds NOT --servers ****")
print("----")
print("-c "+str(DRIVE_SIZE)+" | Using DRIVE|OSD_SIZE (TB) "+str(DRIVE_SIZE))
print("-o "+str(OSD_COUNT)+" | Using OSD_COUNT "+str(OSD_COUNT))
print("Results in RAW (TB) "+str(RAW))
print("----")
print("-k "+str(EC_K)+" | Using K (min copy) of "+str(EC_K))
print("-m "+str(EC_M)+" | Using M (resiliancy) of "+str(EC_M))
print("----")
print("EFFICIENCY RATIO")
print(str(round(EFFICIENCY, 3)))
print("----")
print("FULL CAPACITY (TB) AT 100% **NOT RECOMMENDED!**")
print(round(FULL_USAGE, 3))
print("----")
print("80% CAPACITY (TB) - RECOMMENDED MAX FOR CEPH (SAFE CAPACITY RESERVERVATION)")
print(round(EIGHTY_FULL_USAGE, 3))
if args["table"] == True:
from tabulate import tabulate
if OSD_COUNT == 0:
table_output=[[str(DRIVE_SIZE),str(DRIVE_PER_SERVER),str(SERVER_COUNT),str(EC_K),str(EC_M),str(round(EFFICIENCY, 3)),str(round(FULL_USAGE, 3)),str(round(EIGHTY_FULL_USAGE, 3))]]
headers =['Drive|OSD Size(TB)','Drives|OSD Per Server','Servers','K','M','EFFICIENCY RATIO','100% CAPACITY (TB)','80% CAPACITY (TB)']
if OSD_COUNT > 1:
table_output=[[str(DRIVE_SIZE),str(OSD_COUNT),str(EC_K),str(EC_M),str(round(EFFICIENCY, 3)),str(round(FULL_USAGE, 3)),str(round(EIGHTY_FULL_USAGE, 3))]]
headers =['Drive|OSD Size(TB)','nOSDs','K','M','EFFICIENCY RATIO','100% CAPACITY (TB)','80% CAPACITY (TB)']
print(tabulate(table_output, headers, tablefmt="heavy_grid"))