Skip to content

LeeC77/sunsynk

Repository files navigation

SunSynk Binding

This binding integrates the Sun Synk Connect web services. This binding is used to connect your openHAB system with Sun Synk Connect (where you log in and find Your Inverters). The binding supports discovery via configuring your login and password in an openHAB bridge. From the binding, you will get status of your inverters and also command channels where you can control them. Since the binding uses a polling mechanism, there may be some latency depending on your setting regarding refresh time.

Sun Synk Connect

Introduction

You will require to have installed a Sun Synk inverter with a WiFi Data logger e-linter connected to the Sun Synk App or Connect. See Data Logger set up or Sun Synk Web. It is recommended, but not necessary that the "data interval" of your Gateway is set via Sun Synk Connect to 60s for best time latency. If you do not have that setting available you can request it set via Sun Synk or your installer or you can ask for an User Level Access Change Request

This binding uses your Sun Synk Connect credentials to access Sun Synk's web services via an OpenHAB Bridge (SunSynk Account). The bridge manages the account authentication and the discovery of SunSynk Inverters.

Acknowledgements:

Supported Things

Name Thing type Supported Thing
SunSynk Account Bridge Thing account
SunSynk Inverter Thing inverter

Discovery

  1. Add the sunsynk binding.
  2. Add a new thing of type SunSynk Account via the SunSynk Binding and configure with username and password.
  3. Go to Inbox press [+] and via the SunSynk Account start discovery [Scan] of inverters.
  4. Inverters should appear in your inbox!

The SunSynk Account bridge thing will discover connected inverters through the UI Scan service. When using the UI Scan service all the parameters for an Inverter Thing are discovered.

  • Inverter Serial maps to the Sun Synk Connect inverter serial number
  • Inverter Name maps to the Sun Synk Connect inverter alias
  • Refresh time (advanced) default 60s; determines the interval between polls of Sun Synk Connect. A value above 60 is enforced. When setting this remember your inverter values are only published by Sun Synk Connect at the rate set by "data interval".

The refresh rate is limited to once every 60s to prevent too many requests from the Sun Synk Connect API, although there is no rate limit, the Sun Synk data is fully refreshed at the "data interval" set in Sun Synk Connect, at best that is every 60s. This can mean the data in openHAB is more than 1 minute delayed from real-time. Commands sent (from openHAB) to Sun Synk are buffered up until the next refresh interval and as they take a while to propagate through to your inverter, some channels are not refreshed (read back) from Sun Synk Connect until the next minute.

The SunSynk Account requires the user e-mail address and password used to login to Sun Synk Connect.

  • The bridge Thing UID is of the form sunsynk:account:abcdef1234
  • The inverter Thing UID is of the form sunsynk:inverter:abcdef1234:<gateway serial><inverter serial>

where <gateway serial> and <inverter serial> are discovered from Sun Synk Connect.

Thing Configuration

sunsynkaccount Bridge Thing Configuration

Name Type Description Default Required Advanced
email text Email address used to login Sun Synk Connect N/A yes no
password text Password to access the Sun Synk Connect account N/A yes no

sunsynk:inverter: Thing Configuration

Name Type Description Default Required Advanced
alias text The Sun Synk Connect inverter alias N/A yes no
sn text The Sun Synk Connect inverter serial number N/A yes no
refresh integer Interval the device is polled in sec 60 yes yes

Channels

The SunSynkAccount has no channels. The SunSynk Inverter has the following channels

Channel Type R/W Description Advanced
battery-SOC Number R Inverter battery % charge no
battery-grid-voltage Number R Battery dc electric-voltage no
battery-grid-current Number R Battery dc electric-current no
battery-grid-power Number R Battery dc electric-power no
battery-temperature Number R Battery temperature no
inverter-ac-temperature Number R Inverter ac temperature no
inverter-dc-temperature Number R Inverter dc temperature no
inverter-grid-power Number R Inverter ac electric-power no
inverter-grid-voltage Number R Inverter ac electric-voltage no
inverter-grid-current Number R Inverter ac electric-current no
inverter-solar-energy-today Number R Solar dc energy generated today no
inverter-solar-energy-total Number R Solar dc energy generated to date no
inverter-solar-power-now Number R Solar dc electric-current no
interval-1-grid-charge Switch R/W Interval 1 grid charge on/off yes
interval-1-grid-time DateTime R/W Interval 1 start grid charge time yes
interval-1-grid-capacity Number R/W Interval 1 battery charge target yes
interval-1-grid-power-limit Number R/W Interval 1 charge power limit yes
interval-2-grid-charge Switch R/W Interval 2 grid charge on/off yes
interval-2-grid-time DateTime R/W Interval 2 start grid charge time yes
interval-2-grid-capacity Number R/W Interval 2 battery charge target yes
interval-2-grid-power-limit Number R/W Interval 2 charge power limit yes
interval-3-grid-charge Switch R/W Interval 3 grid charge on/off yes
interval-3-grid-time DateTime R/W Interval 3 start grid charge time yes
interval-3-grid-capacity Number R/W Interval 3 battery charge target yes
interval-3-grid-power-limit Number R/W Interval 3 charge power limit yes
interval-4-grid-charge Switch R/W Interval 4 grid charge on/off yes
interval-4-grid-time DateTime R/W Interval 4 start grid charge time yes
interval-4-grid-capacity Number R/W Interval 4 battery charge target yes
interval-4-grid-power-limit Number R/W Interval 4 charge power limit yes
interval-5-grid-charge Switch R/W Interval 5 grid charge on/off yes
interval-5-grid-time DateTime R/W Interval 5 start grid charge time yes
interval-5-grid-capacity Number R/W Interval 5 battery charge target yes
interval-5-grid-power-limit Number R/W Interval 5 charge power limit yes
interval-6-grid-charge Switch R/W Interval 6 grid charge on/off yes
interval-6-grid-time DateTime R/W Interval 6 start grid charge time yes
interval-6-grid-capacity Number R/W Interval 6 battery charge target yes
interval-6-grid-power-limit Number R/W Interval 6 charge power limit yes
interval-1-gen-charge Number R/W Interval 1 generator charge on/of yes
interval-2-gen-charge Switch R/W Interval 2 generator charge on/of yes
interval-3-gen-charge Switch R/W Interval 3 generator charge on/of yes
interval-4-gen-charge Switch R/W Interval 4 generator charge on/of yes
interval-5-gen-charge Switch R/W Interval 5 generator charge on/of yes
interval-6-gen-charge Switch R/W Interval 6 generator charge on/of yes
inverter-control-timer Switch R/W Inverter control timer on/off yes
inverter-control-work-mode String R/W Inverter work mode 1, 2 or 3 yes
inverter-control-energy-pattern String R/W Inverter energy pattern 1 or 2 yes

Thing Configuration

sunsynk.things

Bridge sunsynk:account: xxx @ "Loft" [email= "user.symbol@domain.", password="somepassword"]{
    Thing inverter E1234567R1231234567890 @ "Loft" [alias= "My Inverter", sn= "1234567890", refresh= 60]
}

Item Configuration

sunsynk.items

Switch                      Interval1GridCharge         "Switch on Grid Charge for Interval 1"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-1-grid-charge"}
Switch                      Interval2GridCharge         "Switch on Grid Charge for Interval 2"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-2-grid-charge"}
Switch                      Interval3GridCharge         "Switch on Grid Charge for Interval 3"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-3-grid-charge"}
Switch                      Interval4GridCharge         "Switch on Grid Charge for Interval 4"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-4-grid-charge"}
Switch                      Interval5GridCharge         "Switch on Grid Charge for Interval 5"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-5-grid-charge"}
Switch                      Interval6GridCharge         "Switch on Grid Charge for Interval 6"         {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-6-grid-charge"}

Switch                      Interval1GenCharge          "Switch on Generator Charge for Interval 1"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-1-gen-charge"}
Switch                      Interval2GenCharge          "Switch on Generator Charge for Interval 2"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-2-gen-charge"}
Switch                      Interval3GenCharge          "Switch on Generator Charge for Interval 3"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-3-gen-charge"}
Switch                      Interval4GenCharge          "Switch on Generator Charge for Interval 4"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-4-gen-charge"}
Switch                      Interval5GenCharge          "Switch on Generator Charge for Interval 5"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-5-gen-charge"}
Switch                      Interval6GenCharge          "Switch on Generator Charge for Interval 6"    {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-6-gen-charge"}

DateTime                    Interval1GridTime           "Time for Interval 1"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-1-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}
DateTime                    Interval2GridTime           "Time for Interval 2"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-2-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}
DateTime                    Interval3GridTime           "Time for Interval 3"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-3-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}
DateTime                    Interval4GridTime           "Time for Interval 4"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-4-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}
DateTime                    Interval5GridTime           "Time for Interval 5"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-5-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}
DateTime                    Interval6GridTime           "Time for Interval 6"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-6-grid-time", widget="widget:rlk_datetime_standalone"[label="Time Picker"]}

Number:Dimensionless        Interval1GridCapacity       "Charge Target Interval 1"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-1-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}
Number:Dimensionless        Interval2GridCapacity       "Charge Target Interval 2"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-2-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}
Number:Dimensionless        Interval3GridCapacity       "Charge Target Interval 3"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-3-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}
Number:Dimensionless        Interval4GridCapacity       "Charge Target Interval 4"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-4-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}
Number:Dimensionless        Interval5GridCapacity       "Charge Target Interval 5"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-5-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}
Number:Dimensionless        Interval6GridCapacity       "Charge Target Interval 6"                     {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-6-grid-capacity", widget="oh-slider-card",listWidget="oh-slider-item"[title="Target SOC",subtitle="Set % SOC"]}

Number:Power                Interval1GridPowerLimit     "Max Charge Power Interval 1"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-1-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}
Number:Power                Interval2GridPowerLimit     "Max Charge Power Interval 2"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-2-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}
Number:Power                Interval3GridPowerLimit     "Max Charge Power Interval 3"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-3-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}
Number:Power                Interval4GridPowerLimit     "Max Charge Power Interval 4"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-4-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}
Number:Power                Interval5GridPowerLimit     "Max Charge Power Interval 5"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-5-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}
Number:Power                Interval6GridPowerLimit     "Max Charge Power Interval 6"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:interval-6-grid-power-limit", listWidget="oh-slider-item"[title="Target Power Limit",subtitle="Set Limit in Watts", min=0, max=8000,step=1000]}

Number:Dimensionless        BatterySOC                  "Battery SOC [%s]"                             {channel ="sunsynk:inverter:xxx:1234567R1231234567890:battery-SOC"}
Number:ElectricPotential    BatteryGridVoltage          "Battery Grid Voltage"                         {channel="sunsynk:inverter:xxx:1234567R1231234567890:battery-grid-voltage"}
Number:ElectricCurrent      BatteryGridCurrent          "Battery Grid Current"                         {channel="sunsynk:inverter:xxx:1234567R1231234567890:battery-grid-current"}
Number:Power                BatteryGridPdower           "Battery Grid Power"                           {channel="sunsynk:inverter:xxx:1234567R1231234567890:battery-grid-power"}
Number:Temperature          BatteryTemperature          "Battery Temperatue "                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:battery-temperature"}
Number:Temperature          InverterACTemperature       "Inverter AC Temperature"                      {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-ac-temperature"}
Number:Temperature          InverterDCTemperature       "Inverter DC Temperature"                      {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-dc-temperature"}
Number:Power                InverterGridPower           "Inverter Grid Power"                          {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-grid-power"}
Number:ElectricPotential    InverterGridVoltage         "Inverter Grid Voltage"                        {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-grid-voltage"}
Number:ElectricCurrent      InverterGridCurrent         "Inverter Grid Current"                        {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-grid-current"}
Number:Energy               InverterSolarEnergyToday    "Inverter Energy Today"                        {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-solar-energy-today"}
Number:Energy               InverterSolarEnergyTotal    "Inverter Enery Gross"                         {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-solar-energy-total"}
Number:Power                InverterSolarPowerNow       "Inverter Power"                               {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-solar-power-now"}

Switch                      Interval6ControlTimer       "Switch on System Mode Timer"                  {channel="sunsynk:inverter:xxx:1234567R1231234567890:inverter-control-timer"}
String                      InverterControlWorkMode     "System Work Mode 0, 1 or 2"                   {channel="sunsynk:inverter:a1a6340bc0:E4701229R3312211229948:inverter-control-work-mode"}
String                      InverterControlPattern      "System Mode Energy Pattern 0 or 1"            {channel="sunsynk:inverter:a1a6340bc0:E4701229R3312211229948:inverter-control-energy-pattern"}

DateTime Widget

The items file above adds Metadata: Default Standalone widget: rlk_datetime_standalone to the DateTime items. Only the time portion of the DateTime item is important.

Be sure to understand the time zone set up for the inverter, this can either be synchronised with Sun Synk servers, which in the UK at least applies daylight saving, or free-wheeling locally. The times set in the DateTime items using the widget are not adjusted to any time zone and are sent to the SunSynk API as Strings where they will be applied directly to your inverter. This is in contrast to other solar / energy APIs that use Zulu (GMT) time.

Installation

Place the .jar file into your addons directory. See the "Through manually provided add-on" section of Installation of Add-ons.

Trouble Shooting

This first version of the binding has been built against 4.2.0-SNAPSHOT - Build #3989, currently its only available as a .jar file

org.openhab.binding.sunsynk-4.2.0-SNAPSHOT

Although the binding is written to find multiple Inverters for each Sun Synk Connect account, testing has been against an account with a single inverter.

Sun Synk account and inverter versions are:

  • Gateway Model EESW-D205
  • Gateway COMM Type Wi-Fi
  • Gateway HW AEW2-0005-03
  • Gateway SW 4790123B24R
  • Inverter 8.0 kW
  • Inverter Type Energy Storage
  • Inverter SW M 5.3.8.4 / S 1.5.1.5 / C E.4.3.0
  • Connect App Version 1.11.12

Debugging

After installation, to gain further information on any issues you encounter you can turn on Debug Logging either through the karaf console or through the openHAB UI.

Via Console:

log:set DEBUG org.openhab.binding.sunsynk

Via UI:

Log on to your local openHAB as admin and follow the menus.

  • Settings > Add-on-Store > Bindings
  • Scroll down to find the binding and click on its title, click the cog and select the level "Debug" on the right.

You should now be able to see debug data in the openhab.log.

Source Code

For those that are interested the source code is here.

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published