Libraries and test sketches for the various electronics (sensors, etc.).
Monitors the pressure of the braking exhaust valves, alerting the team in case of any irregularity.
Outputs: Pressure (psig), range: 0 to 1000 psig
Monitors the pressure of the braking exhaust valves, alerting the team in case of any irregularity.
Outputs: Pressure (psi), range: 0 to 200 psi
Measures the temperatures near a) the front wheel, b) the center of the pod, and c) the rear wheel.
Outputs: Temperature (Celcius), range: -40 to 150 C
Measures the temperature around the center of the pod. Sensor is intended to be used in auxiliary, to obtain diagnostic data for pod improvement.
Outputs:
- Die temperature (Celcius), range: unspecified in official documentation
- Object temperature (Celcius) (calculated from die temp and die voltage), range: -40 to 125 C
Measures the distancee between the bottom of the pod’s frame to the top of the track I-beam. Used to inform emergency stopping procedures.
Outputs:
- Distance (mm), range: 30 to 80 mm
- An indication if there exists an error(or if it cannot detect an object within the range)
Monitors the flowrate of the watercooling loop.
Outputs:
- Frequency (Hz)
- Flow rate (GPM), range: 0.26 to 5.28 GPM
9-axis accelerometer, gyroscope, and magnetic field sensor. Sensor is intended to be used in auxiliary, obtained data for pod improvement.
Outputs:
- Acceleration X, Y, Z (milli-gees), range: ±2000 mg (default, configurable to up to +-16000 mg)
- Gyro values X, Y, Z (deg/sec), range: ±250 deg/sec (default, configurable to up to +-2000 deg/sec)
- Magnetic values X, Y, Z (milli-Gauss), range: ±48000 mG
- Sensor temperature (C), range: -40 to 85 C
Engages brakes via digital output control of a MOSFET driving a solenoid (NORMALLY OPEN, i.e. digital low = open solenoid = brakes engaged). Once engaged, brakes do not disengage. Fails safe (to engaged).
Discharges the inverter via digital output control of a MOSFET driving a relay (NORMALLY OFF, i.e. digital high = closed relay = inverter discharging). Fails safe (relay closed, discharging).